Context Plus XFP501E 1 Loop 16 Zone Addressable Fire Alarm Panel

Specifications:

- Certified: EN54-2/4 (LPCB)

- Protocol: C-TEC CAST

- Mains: 230V AC, 50/60Hz, 350mA max

- PSU: 27V DC nominal, 1.4A max @ 230V AC

- Quiescent Current: 50mA (unloaded)

- Battery: 2 x 12V 3.2Ah VRLA (series)

- Loop Drivers: 1

- Max Loop Output: 500mA @ 40V

- Loop Length: Up to 1km

- Devices per Loop: Max 255

- Sounder Circuits: 2 (500m max each)

- Sounder Output: 400mA max

- EOL Resistor: 6.8kΩ, 0.25W

- Relays: 3 x programmable, 1 x fault relay (1A @ 30V DC)

- Aux Power: 24V DC (19.5–28V), 100mA max

- Inputs: 2 x programmable (0V trigger, 27V max)

- PC Connection: RS232 (via XFP507 kit), no printer

- Display: 2x40 backlit LCD, 16 zonal LEDs + system indicators

- Wiring: Max conductor size 1mm²

- Networking: Optional RS485 (XFP761), up to 8 panels/repeaters, 1km/500m max

- Size: 380 x 235 x 96mm

- Material: Plastic (RAL7035 textured)

- IP Rating: IP30

- Weight: 1.8kg (excl. batteries)

- Operating Temp: -5°C to +40°C, RH 95% max

- Price mentioned per piece

PKR 210000.00

Context XFP502 32 Zone Networkable Addressable Control Panel

Specifications:

- Protocol: C-TEC CAST

- Mains Supply: 230V AC, 50/60Hz

- Rated Current: Max. 680mA

- Internal PSU: 27V DC nominal, 3A max @ 230V AC

- Quiescent Current: 100mA (2 unloaded loops)

- Battery: 2 x 12V 7Ah VRLA (in series)

- Loop Drivers: 2

- Loop Output: Max. 500mA @ 40V; Max. 1km loop length; 255 devices/loop

- Sounder Circuits: 2 conventional, 500m max length each

- Sounder Output: Max. 400mA

- EOL Resistor: 6.8kΩ, 0.25W (Blue-Grey-Red-Gold)

- Material: Metal

- IP Rating: TBC

- Weight: 4.5kg (excluding batteries)

- Operating Conditions: -5°C to +40°C; Max. 95% RH

- Relays:

3 x Programmable (via C&Es)

1 x Fault Relay (active = no faults)

SPCO, 1A @ 30V DC max

- Display/Indicators:

2x40 backlit LCD

32 Zonal LEDs

Fire, Fault, Pre-Alarm, Test, Disablement, etc.

- Connections: Max conductor size 1mm²

- Expansion:

Optional AFP711 card for RS485 networking

Up to 8 panels/repeaters, 1km (network), 500m (repeater)

- Dimensions:

Base: 410mm (W) x 250mm (H) x 80mm (D)

Lid: 439mm (W) x 274mm (H) x 7mm (D)

- Aux Power Output: 24V DC (19.5V–28V), 100mA max, resettable fuse protected

- Aux Inputs: 2 programmable (trigger to 0V), 27V max, non-latching

- PC Connection: RS232 via Molex (XFP507 kit); no printer support

- Price mentioned per piece

PKR 315000.00

Context Plus EP203 LPCB Approved 3 Zone Fire Suppression Extinguishant Alarm Panel

Specifications:

- Mains supply: 230V 50/60Hz.

- Mains rated current: 810mA max.

- Internal power supply: 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

- Total output current limited to: 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

- Quiescent current: 40mA (on mains fail). Zone quiescent 2mA max.

- Max battery size and type: 2 x 12V 7Ah VRLA connected in series.

- No. of detector zone circuits: 3 @ 19-28Vdc (Max. length per circuit is 250m).

- Max. devices per detector zone: 20 detectors (or 32 detectors/manual call points combined).

- No. of conventional sounder circuits: 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

- EOL resistor value: 6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

- Max. sounder output current: 3 x 200mA.

- Auxiliary relays: Six: (1) Fire;

(2) Local Fire;

(3) Extract Fan;

(4) 1st Stage;

(5) 2nd Stage;

(6) Fault. Volt free single pole changeover. Max. switch current 1A;

Max. switch voltage 30Vdc. Five additional relays

- Other outputs: Extinguishant release (21-28Vdc, rated at 1A for 5 mins).

Programmable to delay by 0-60 seconds;

to be active for 1-300 seconds and to flood for 60-1800 seconds.

- Auxiliary inputs: Six: (1) Manual Release;

(2) Flow Switch;

(3) Low Pressure;

(4) Mode;

(5) Hold;

(6) Abort. 8K-2KΩ normal;

1.8K-200Ω active;

150-0Ω short circuit.

EOL value: 6K8 +/-5%, 0.25W.

- Indicators: Multiple indicators are provided – refer to the EP203 instructions for details.

- Expansion connections: Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power)

and/or up to 8 x Ecomomy status units (2 wire power + 2 wire mode select).

- Product dimensions (mm): 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

- Construction & finish: Metal back box; metal chassis' plastic lid.

- IP Rating: IP30.

- Weight: 4.2kg (without batteries).

- Operating conditions/temperature: -5ºC to +40ºC. Max relative humidity: 95%.

Contact us For Quote

Context Plus FF516 16 Zone Fire Control Expandable Model Panel

Specifications:

- Mains supply: 230V 50/60Hz.

- Mains rated current: 700mA max.

- Internal power supply: 27V nominal.

- Total output current limited to : 3A @ 230V.

- Quiescent current: 90mA

- Max battery size and type: 2 x 12V 7Ah VRLA connected in series.

- No. of detector zone circuits: 16 (Max. length per circuit is 500m).

Can be extended to 28 zones using FF501Z 4 Zone - extender PCB kits.

- Call point resistor value: 470 to 680Ω.

- Max. devices per detector zone: 20 detectors (max. detector current 2mA).

- No. of conventional sounder circuits: 4 (Max. length per circuit is 500m).

- EOL resistor value: 6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

- Max. sounder output current: 3mA (to all outputs). Outputs are fused at 1A.

- Auxiliary relays : 1 x onboard relay (1A, 30 VDC, follows sounders).

- Open collector outputs: 2 x Fire and 1 x Fault output available via optional FF574X expansion loom. Max. sink current 100mA.

- Auxiliary inputs: Class change input available via optional FF574X expansion loom.

- Indicators: Mains On;

Gen Fire;

Zone Fire;

Zone Fault (S/C, O/C, head out, Zone disabled);

Sndr Fault;

Processor Fault;

Batt/PSU Fault;

Aux O/Ps Disabled;

Fault Sounder (fault, silenced fire and delayed sndrs)

- Controls: External (key operated): Reset/Test Scroll;

Silence Alarm/Fault Sounders;

Evacuate;

Disable. Internal: OMT;

Sounder Walk Test;

Sounder Isolate;

Sounder Delay;

S/C equals fire;

Non-latching zones.

- Product dimensions (mm): 521 W x 334 H x D 140mm.

- Construction & finish: Metal lid and base.

- IP Rating: IP30.

- Weight: 9.5kg.

- Operating conditions/temperature: -5ºC to +40ºC. Max relative humidity: 95%.

Contact us For Quote

Context Plus EP215 Hold Off Abort Control Button for Extinguishing Systems

Specifications:

- Quiescent current: 0mA (none).

- Alarm current: Determined by the type of control equipment and

- number / type of field devices connected to the system.

- Controls: Green button.

- Product dimensions (mm): 87 H x 87 W x 58 D mm. Surface or flush mounting.

- Construction & finish: Polycarbonate. Green push button, yellow call point housing, black back box.

- IP Rating: IP24.

- Weight: TBC

- Operating conditions/temperature: -0ºC to +65ºC. Max. relative humidity 95% non-condensing

Contact us For Quote

Context Plus Polycarbonate Ingress Protection Conventional Manual Call Point Emergency and Fire Alarm

Specification:

- Connection Details: See Instruction manual

- Cable Termination: 0.5-2.5mm2

- Maximum Voltage: 30VDC

- Current Rating (switch only): 2 Amps

- Humidity: 93± 3% non-condensing

- Operating Temperature: -100C to +550C

- Storage Temperature: -100C to +550C

- Ingress Protection (IP) Rating: IP24D

- Material: Polycarbonate PC/ABS Acrylonitrile Butadiene Styrene

- Weight: 180g

- Colour: Red

- Price mentioned per piece